Ventilation & air quality

Industrial ventilation and air conditioning

Create a reliable balance between extraction, fresh air supply and thermal comfort to ensure a healthy environment in your production areas.

StudyDesignCommissioning
Industrial installations — Industrial ventilation & fresh air AIRPRO EXPERTISE
Fresh airintroduced and controlled to dilute diffuse pollutants and renew the atmosphere
BUILDING SURVEY

Ventilation begins with understanding where the air wants to go.

A workshop is not simply a space in which to circulate air. Machinery, doors, temperature differences and existing extraction systems create air movements that can sometimes work against the desired objective.

AIRPRO draws up this layout plan before determining the airflow rates, in order to treat the occupied area without unnecessarily ventilating the entire building.

Useful volume

Height, geometry, openings and areas actually occupied determine how air can flow through the building.

Emissions

Heat, steam, fumes or aerosols are identified, quantified and linked to production cycles.

Air flow

Doors, prevailing draughts, existing extraction systems and machinery already create airflow patterns that need to be understood.

Airflow analysis

Extracting without compensating merely shifts the problem.

Effective extraction requires a well-organised air supply. Otherwise, the building will draw in air through its doors, disrupt sensors and create uncontrolled draughts.

Visualisation of fresh air and exhaust air flows in a ventilated industrial workshop

Extract

Remove the pollutant or heat at the point of origin.

Compensate

Re-establish a consistent flow rate to prevent uncontrolled negative pressure.

Distribute

Deliver fresh air to the relevant areas without causing draughts that cause discomfort.

Balancing

Adjust the systems to maintain the specified flow rates in the various scenarios.

Exhaust air+Balancing air+Controlled air distribution=Balanced workshop
OCCUPIED AREA

Ventilate people and processes, not cubic metres.

The air distribution system is designed to deliver clean air to where staff are working, and then direct emissions towards their collection or extraction points.

Cross-section of a workshop with fresh air supply and localised air intake at the machines
READING THE DIAGRAM

Air intake, distribution and extraction in a single view.

  • Effective airflowJob-oriented
  • Hierarchical extractionPrioritise the source material
  • Variable speed systemsSuitable for production
Ventilation strategies

Three phenomena, three different solutions.

A system may combine several strategies. The choice depends on the nature of the emissions and their ability to disperse within the workshop.

Localised emissions

Source capture

Capture fumes, vapours or heat before they disperse.

Priority: to enclose the source with just the necessary airflow.
Diffuse pollution

Dilution ventilation

Renew the air when emissions are distributed throughout the space.

Priority: to avoid dead zones and control airflow.
Heat load

Air sweeping and stratification

Removing heat by utilising the natural movement of hot air.

Priority: protect the occupied area before treating the entire space.
On-site measurements

Make decisions based on data, not on an isolated air change rate.

The measurements link the observed behaviour to the actual conditions within the network. They make it possible to distinguish between a lack of flow and a problem with intake, compensation or distribution.

Airflow rates & velocities

At air outlets, within ductwork and around openings.

Pressures

Understanding building balance and pressure drops.

Temperature & humidity

In the occupied zone, at the sources and in the extracted air.

Production cycles

In order to identify peak loads and simultaneous demand.

Preparing the design study

The information that makes the initial discussion meaningful.

A plan and a few observations are all that is needed to get started. AIRPRO turns these elements into hypotheses to be tested in the field.

Describe my workshop or call +33 7 57 69 08 40
  • Building layout and available headroom
  • List of machinery and emission sources
  • Extraction flow rates already installed
  • Critical indoor and outdoor temperatures
  • Working hours, workforce and production cycles
  • Intended purpose: air, heat or process
TECHNICAL QUESTIONS

Clarify the balance before sizing.

Initial answers to frequently asked questions about ventilation and fresh air supply in industrial environments.

Why is it necessary to replace the air extracted from a workshop?

Without a controlled supply of air, the building will develop a negative pressure, and the extraction system will become less effective. Pressure equalisation also allows the flow of fresh air to be managed without creating annoying draughts.

General ventilation or local exhaust ventilation?

Source extraction remains the priority for localised emissions. General ventilation supplements the system to deal with heat gains and diffuse pollutants that cannot be captured locally.

What data is required for an industrial ventilation study?

Volumes, openings, occupancy, machinery, emissions, existing flow rates and thermal constraints form the initial assessment. On-site measurements are then carried out to confirm the assumptions.

AIRPRO engineer inspecting an industrial air-treatment installation
Your project

Tell us about your industrial requirement.

Describe your installation, issue or objective. An AIRPRO engineer will provide an initial technical assessment.

Tell us about your project

Reply within 1–2 business days

By submitting this form, you agree to be contacted by AIRPRO.